The Precisive® Gas Analyzer is a real-time gas analyzer based on MKS' unique Tunable Filter Spectroscopy (TFS™) platform. The Precisive suite of products are calibrated for the measurement of a wide range of gases across multiple process industries. The real-time, continuous measurement capability provides immediate analysis ensuring control of critical process parameters.
PRECISIVE-5-271
Gas Analyzer, Tunable Filter Spectroscopy, Syngas Composition
0.0
0.0
Tunable Filter Spectroscopy
CH4: 0-25% C2H6: 0-25% C2H4: 0-20% C2H2: 0-5% CO: 0-50% CO2: 0-50% Balance High Heating Value (HHV) Low Heating Value (LHV) Specific Gravity Wobbe Index (WI) (per ISO 6976: 2016)
<strong>Gas channels:</strong> < 0.15 mol% HHV, LHV & WI: <0.4% of Reading or <0.2 MJ/ m3 (greater of) Specific Gravity: <0.1% of Reading
PRECISIVE-5-282
Gas Analyzer, Tunable Filter Spectroscopy, Natural Gas Calorific Value, Wobbe Index
0.0
0.0
Tunable Filter Spectroscopy
CH4: 50-100% C2H6: 0-20% C3H8: 0-10% C4+: 0-10% CO2: 0-20% Balance High Heating Value (HHV) Low Heating Value (LHV) Specific Gravity Wobbe Index (WI) (per ISO 6976: 2016) Methane Number
Gas Channels: <0.05 mol% HHV, LHV & WI: <0.2% of Reading or <0.1 MJ/m3 (greater of) Specific Gravity: <0.05% of Reading
Additional CAD file downloads are not available for this product.
precisive-application-specific - Drawings
Additional drawings are not available for this product.
Specifications
Type
Real-time Gas Analyzer
Measurement Technique
Tunable Filter Spectroscopy (TFS™)
Zero Drift
Not to exceed 0.2% per month; Maximum of 0.5% throughout life of bulb (~36 months)
Sample Pressure
0.1-5 psig
Flow Rate
0.1-2 L/min Contact MKS for higher or custom ranges
Sample Cell
0.35m pathlength, 100mL volume
Weight
12kg (25.8lbs)
Power Requirements
24 VDC or 100 - 240 VAC
Operating Temperature
-20 to 50°C -20 to 48°C (ATEX)
Communication
Modbus over Ethernet or RS485
Dimensions
Width: 17.25 in. (438.2 mm) Depth: 6.60 in. (167.6 mm) Height: 11.25 in. (285.8 mm)
Certifications
Class I, Division2, Group A, B, C and D, T4 Class I, Zone 2, Aex nA nC IIC T4 Gc Ex nA nC nL IIC T4 Gc Sira 13ATEX4316 Ex ec nC IIC T4 Gc IECEx CSA 14.0049 Ex ec nC IIC T4 Gc IP66, Type 4
Simplified schematic of light absorption spectroscopy
The Precisive TFS™ (Tunable Filter Spectrometer) sensor platform consists of a light source, a sample cell (for gases, liquids or solids), a wavelength separating element (spectrometer) and a photo-detector. The wavelength separating element "slices" the wavelength components of the broadband light source which then interacts with the sample molecules. Some of the wavelength components are absorbed and some are transmitted through without any absorption.
Advanced Spectral Decomposition Algorithm
Light absorption spectroscopy with advanced spectral decomposition algorithm
Precisive TFS™ Tunable Filter Spectrometers use an advanced spectral decomposition algorithm. The resulting spectrum is called absorption spectrum, which acts as "fingerprints" which are used to identify the sample components and/or quantify the composition of the sample.
Enter your email address below to reset your account password.
Password Reset
Email Verification Required
Cart Items Updated
Remove Product
Remove this product from your comparison list?
Check Order Status
Provide an order number and postal code to check the status of an order or download an invoice for an order that has shipped. Login to view your complete order history.
Sign In Required
To access this and other valuable technical resources, please sign in or register for a new online account.